How to set maxcc in jcl

WebMar 25, 2014 · The short answer to your question is No. You can't magically pass the highest Return Code, or Return Code from a previous step, to a program just with JCL. The longer answer is Yes, it will probably be possible to do what you want, however you have asked us how to provide the solution you have come up. WebUse the SETRC function to set the job step return code to a specified value. Use conditional parameters to set the return code based on an existing return code value. Syntax .-IFOP=EQ-. >>-SETRC--RC=rc--+---------+--+----------+--------------------->< +-IFOP=GE-+ '-IFRC=rc2-'

About MAXCC codes - JCL - IBM Mainframe Forum

WebMy requirement here is to set the Maxcc=0 if the FTP is successful in either of the three steps. I have already tried the below piece of code:- if ( step020.RC =0 step030.RC =0 … WebThanks Varun. Is there any other utilities to determine this? -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Varun Manocha Sent: Tuesday, February 26, 2008 4:34 PM To: [email protected] Subject: Re: How to find uncatalog datasets.Mani, I use a JCL as below : //STEP01 EXEC … grandview small engine repair https://politeiaglobal.com

How to set maxcc=0??? - mainframewizard.com

WebSYS1.IMAGELIB data set open with the IMGLIB macro when checkpoint taken. Programmer Response: Ensure that all IMAGELIB DCBs are closed prior to issuing CHKPT. See also IMGLIB. 251: S23F: A data set that was not a checkpoint data set at checkpoint time was found to be open as a secure checkpoint data set at restart time. WebThe SET command may be used to set either the LASTCC value or the MAXCC value to a specific value. Frequently the SET command is used to reset the return code (s) to a value of 0 following an expected warning level error condition. Example: Let us see an example how to delete and define VSAM dataset in single JCL step using IF statement. WebJan 29, 2010 · Condition Codes (sometimes called Return Codes) are simply a method to let the caller know how the program ended. The program itself sets the COND CODE prior to ending. The degree of severity for certain errors conditions are typically related to the rising COND CODE. 0 = OK 4 = Informational 8 = Warning 12 = Error 16 = Severe error grandview sioux city

Setting MAXCC in JCL using IDCAMS mainframegeek

Category:VSAM - Access Method Services - VSAM Tutorial - IBMMainframer

Tags:How to set maxcc in jcl

How to set maxcc in jcl

How to set a zero return code for the Control-M for z/OS ... - BMC …

WebDec 15, 2011 · MY requirement is to get same record counts using JCL - Syncsort. MY Input File contains the packed decimal values in 58-60 position. I need to get the record count when the input in between 01 and 05 range. Actually I tried to convert PD values into ZD and compare with C'01' and C'05'. I could not get the result. WebMay 23, 2011 · But, my requirement is that, "no record found" situation is acceptable and the job has to end with RC 0. I tried the below code: //STEP01 EXEC PGM=FILEAID ..... .... // IF STEP01.RC = 8 THEN //STEP02 EXEC PGM=IDCAMS //SYSPRINT DD=* SET MAXCC = 0 // ENDIF Although STEP02 was executed the RC from the job was 8. Please advice. …

How to set maxcc in jcl

Did you know?

WebMay 13, 2011 · How to setup MAXCC of JCL using IDCAMS? You just need to code SET MAXCC= in the SYSIN dataset of IDCAMS. What are the limits for SET … WebJan 25, 2024 · IF LASTCC =8 ; SET MAXCC=0. Step 2: Create a new VSAM File DEFINE VSAM-FILE_NAME (COND=(0,LT,STEP1) ... Step3: Next, you must run a JCL command (IDCAMS - Define Cluster) with step-2 results/output (sorting mechanisms) as input. Step4: Finally, to load the flat file into VSAM, use the IDCAMS REPRO command.

WebMay 13, 2011 · How to setup MAXCC of JCL using IDCAMS? You just need to code SET MAXCC= in the SYSIN dataset of IDCAMS. What are the limits for SET …

Web&MAXCC contains the highest return code returned by a nested CLIST or by a TSO/E command, subcommand, or CLIST statement in the currently executing CLIST. &MAXCC is not set when a subprocedure returns to the CLIST. You can use &MAXCC with &LASTCC to determine error conditions. WebUsing the SET command and MAXCC Parameter In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, set the maximum condition code to 8. IF MAXCC=0 THEN DO LISTCAT CATALOG (AMASTCAT/MST27) ENT (MN01.B005) PRINT INFILE (AJK006) END

WebMay 9, 2006 · As far as my Knoledge goes, The SET statement is used to assign values to symbolic parameters that appear within a job's JCL or within JCL procedures called by the job. Ex: In the below example we can set the program name and pass it. // SET PGM=PGMA. . . . //SYSIN DD [email protected] (&PGM),DISP=SHR. //SYSOBJ DD …

WebJul 7, 2005 · The command SET MAXCC = x is used to override internal return code of IDCAMS. Really there are two Retrun code in IDCAMS that are LASTCC and MAXCC, but … grandview small motorsWebMay 17, 2024 · 0. The input file and output file is declared as Fixed and is of length 80. But both input and output variables are of length less than 80. They have length of 27.So in player-details and output details add filler variable with length 80 - 27 = 53. Also make sure the input and output file length are 80. Share. chinese takeaway rhooseWebDec 15, 2011 · My requirement here is to set the Maxcc=0 if the FTP is successful in either of the three steps. I have already tried the below piece of code:-if ( step020.RC =0 … chinese takeaway rhosdduWebNov 9, 2024 · Next, you want to automatically copy your four JCL job PDS members residing on z/OS as .txt files and place those files on your local machine. In this case, you'll use FTP. Place the following lines into a .txt file (let’s call the file SampleFTP.txt) and place the file on your desktop (or, for that matter, anywhere on your local Windows ... grandview soccerWebExplanation: In this example, After STEP01 is completed we check the Return code of STEP01 step. if return code is zero then STEP02 step will execute else step STEP03 will be executed. Tips: IF RC = 0 THEN IF STEP1.RC < 12 THEN If you not given the stepname, then the highest return code from all job steps is taken for checking. grandview softball 2022WebNov 18, 2010 · I have requirement as follows,In an input file there will be only one record(FB file) of four characters, I need to check each character and I need to set maxcc based on … grandview smithtownWebJul 10, 2024 · The following requirements can be met using below mentioned JCL utilities: 1. Need to check if a data set is empty or not. If it’s empty I want to skip all other steps. 2. Need to skip certain steps in my job if the input is empty. This would be easiest if a utility would generate a non-zero RC if the input is empty. 3. grandview sofa sumatra